Skip to main content

Table 2 Assay bioanalytical validation parameters of PIO, ALO, GLM, and VLD in human plasma

From: Earth-friendly micellar UPLC technique for determination of four hypoglycemic drugs in different pharmaceutical dosage forms and spiked human plasma

Parameter

PIO

ALO

GLM

VLD

Linearity range (µg/ mL)

5–25

5–25

5–25

5–25

Correlation coefficient (r)

0.9999

0.9998

0.9997

0.9991

Slope

5.5162

8.4906

4.2208

12.0195

Intercept

1.3595

-0.6215

0.3480

-25.3309

LOD (µg/ mL)

0.2972

0.6271

0.9472

1.6301

LOQ (µg/mL)

0.9007

1.9004

2.8702

4.9398

Accuracy (R %)

99.77

98.66

99.37

100.87

Precision

    

Repeatability (RSD%) a

Intermediate Precision (RSD%) b

0.295

0.528

0.280

0.781

0.131

1.680

0.891

1.231

  1. a The intra-day relative standard deviation of (5, 15, and 25 µg/mL) of PIO, ALO, GLM, and VLD in triplicate using the proposed method
  2. b The inter-day relative standard deviation of (5, 15, and 25 µg/mL) of PIO, ALO, GLM, and VLD in triplicate using the proposed method