Skip to main content

Table 5 Application of standard addition technique for determination of SER.DMP and DMP in capsules using the developed chromatographic techniques

From: Chromatographic reversed HPLC and TLC-densitometry methods for simultaneous determination of serdexmethylphenidate and dexmethylphenidate in presence of their degradation products—with computational assessment

Pharmaceutical taken (µg/mL)

HPLC method

TLC densitometric method

Standard added b(μg/mL)

% Recovery of added standarda

Standard addedb (μg/spot)

% Recovery of added standarda

SER.DMP

DMP

SER.DMP

DMP

15

10

101.25

99.75

10

100.07

99.95

10

15

99.45

100.69

15

99.95

100.75

5

20

99.52

99.82

20

99.85

99.92

Mean

 

100.27

100.43

 

99.95

100.31

% RSD

 

0.830

0.824

 

0.963

1.129

  1. aAverage of three different experiments
  2. bEach of both drugs