Skip to main content

Table 7 Comparison between published (Ref.5) and newly developed methods

From: Chromatographic reversed HPLC and TLC-densitometry methods for simultaneous determination of serdexmethylphenidate and dexmethylphenidate in presence of their degradation products—with computational assessment

Parameters

Published method (Ref.5)

Developed methods

HPLC

TLC- densitometric

SER.DMP

DMP

SER.DMP

DMP

SER.DMP

DMP

Chromatographic conditions

 Mobile phase

Trifluoroacetic acid: acetonitrile (70:30 v/v)

5 mM phosphate buffer (pH 5.5): acetonitrile (40:60 v/v)

methanol: chloroform (70:30 v/v)

 Detection wavelength

265 nm

265 nm

220 nm

220 nm

220 nm

220 nm

 Run time

7.33 min

7.33 min

7.75 min

7.75 min

–-

–-

 Retention time Rt

or

2.71 min

7.33 min

7.75 min

4.82 min

–-

–-

 Flow rate (Rf)

–-

–-

0.24 min

0.62 min

Forced degradation (% degradation)

 HCl (0.1N)

  

  Normal condition

3.1%

3.3%

    

 HCl (0.1N)

  Reflux for 2 h at 60 °C

100% verified by TLC, three degradants

100% verified by TLC, one degradant

100% verified by TLC, three degradants

100% verified by TLC, one degradant

 HCl (1N)

  Normal condition

22%

21.5%

N/A

 NaOH (0.1N)

  Normal condition

2.7% %

2.5%

 NaOH (0.1N)

  Reflux for 2 h at 60 °C

100% verified by TLC, two degradants

100% verified by TLC, two degradants

100% verified by TLC, two degradants

100% verified by TLC, two degradants

 NaOH (1N)

  Normal condition

24.9%

20.3%

N/A

Degradation products

 Separation

  Identification of acid degradants

 + 

 + 

 + 

 + 

 Separation

  Identification of alkaline degradants

 + 

 + 

  Confirmation of degradation pathway

confirmed using TLC, IR, 1H-NMR and mass spectroscopy

Method validation

 Linearity range/sensitivity (μg/mL)

4.2–63

0.9to3.5

2.5–25

5–25

5–25

5–25

 LOD (μg/mL)

0.042

0.009

0.051

0.098

0.184

0.115

 LOQ (μg/mL)

0.42

0.09

0.165

0.186

0.202

0.237

 Selectivity (application to lab prepared mixtures in presence of degradants)

Not tested

Not tested

No interference from degradation products,up to 80% acidic & 70% alkaline

No interference from degradation products, up to 80% ( acidic)

No interference from degradation products, up to 80% acidic & 70% alkaline

No interference from degradation products, up to 80% acidic

 Application of standard addition techniquea

 + 

 + 

 Verification of practical outcomes by MDSTb

 + 

 + 

  1. a Accuracy assessment
  2. b Molecular Dynamic Simulation Technique