Skip to main content

Table 3 Statistical analysis of the results obtained by the proposed (SWV) method for determination of FAV in dosage form at RGO/CPE

From: A highly sensitive and green electroanalytical method for the determination of favipiravir in pharmaceutical and biological fluids

Parameters

Avipiravir tablet®

 

Proposed method

Reference methodc [14]

Meana ± S.D.

99.96 ± 0.75

99.25 ± 1.51

t-test

0.95 (2.36)b

 

F-test

4.05 (6.39)b

 
  1. a Mean of five determinations
  2. bThe values in parenthesis are the corresponding theoretical values of t and F at P = 0.05
  3. c Waters Alliance 2695 high-performance liquid chromatography (HPLC) system equipped with a quaternary gradient pump, autosampler and photodiode array detector 2996, Waters VDSpher PUR 100 C18-E column (5 μm, 250 × 4.6 mm)