Skip to main content

Table 1 Statistical analytical parameters for determination of ROS, ATO, EZE and SIM mixture using the proposed MEKC-DAD method

From: Development of a sustainable multianalyte MEKC method for quantitation of the antihyperlipidemic drugs ezetimibe together with three statins. Greenness and whiteness appraisal studies

Parameter

ROS

ATO

EZE

SIM

Wavelength (nm)

243

243

237

237

Concentration range (μg/mL)

10–100

10–100

10–100

10–100

Intercept (a)

− 0.493

− 0.393

− 7.167

4.104

Saa

0.283

0.520

1.224

0.668

Slope (b)

0.506

1.210

1.565

0.768

Sbb

0.005

0.008

0.020

0.009

RSD% of the slope (Sb%)

0.99

0.66

1.28

1.17

Correlation coefficient (r)

0.9996

0.9998

0.9993

0.9995

Sy/xc

0.414

0.762

1.792

1.037

Fd

12,336

20,842

6290

7662

Significance F

4.83 × 10‒14

5.93 × 10‒15

7.12 × 10‒13

3.24 × 10‒13

LODe (μg/mL)

0.52

0.75

0.42

0.64

LOQf (μg/mL)

1.73

2.50

1.40

2.13

  1. aStandard deviation of the intercept
  2. bStandard deviation of the slope
  3. cStandard deviation of residuals
  4. dVariance ratio, equals the mean of squares due to regression divided by the mean of squares about regression (due to residuals)
  5. eLimit of detection
  6. fLimit of quantification