Skip to main content

Table 3 Parameters required for system suitability tests of the proposed HPLC method

From: Greenness assessment of two chromatographic methods developed for the determination of Mupirocin in two binary mixtures along with its impurity

Parameters

Mixture (1)

Mixture (2)

Reference value [25]

FIC

Pseud-D

MUP

FLU

Pseud-D

MUP

MF

Retention time (tR)

2.78

5.37

12.36

13.70

2.37

3.40

4.73

 

Resolution (Rs)

7.77

22.1

7.16

5.34

5.81

≥ 1.5

Tailing factor (T)

1.11

1.18

1.23

1.20

1.18

1.17

1.18

T = 1 for typical symmetric peak

Retention factor (k)

1.05

2.98

8.15

9.14

2.85

1.52

2.5

1–5

Selectivity factor (α)

2.81

2.73

1.12

2.01

1.64

> 1

Column efficiency (N)

3270

2110

101,000

75,100

2604

4779

67,600

Increases with efficiency of the separation

Height equivalent to theoretical plates (HETP)

0.0076

0.0118

0.00024

0.00033

0.0096

0.0052

0.0003

The smaller the value, the higher the column efficiency