Table 5 Determination of ASP, ATV and CLP in laboratory prepared mixtures using the developed HPLC–DAD method

From: An innovative combination of Box-Behnken design and ecofriendly approaches for the simultaneous determination of aspirin, clopidogrel, atorvastatin and rosuvastatin in their fixed-dose combination tablets

Taken (μg/mL)

AUP

Found (μg/mL)

Recovery %

ASP

ATV

CLP

ASP

ATV

CLP

ASP

ATV

CLP

ASP

ATV

CLP

1.5

0.1

0.75

2.083

0.295

0.586

1.493

0.100

0.753

99.53

100.00

100.40

5

0.5

5

5.991

1.031

3.849

4.938

0.494

4.995

98.76

98.80

99.90

7.5

1

7.5

8.876

1.96

5.789

7.481

0.993

7.516

99.75

99.30

100.21

15

2

7.5

17.255

3.805

5.775

14.866

1.982

7.498

99.11

99.10

99.97

25

5

25

28.593

9.323

19.269

24.860

4.942

25.039

99.44

98.84

100.16

50

10

35

57.128

18.567

26.963

50.012

9.901

35.040

100.02

99.01

100.11

        

Mean

99.44

99.18

100.13

        

 ± SD

0.451

0.443

0.178

        

 ± RSD%

0.454

0.447

0.178