Skip to main content

Table 6 Determination of ASP, ROS and CLP in laboratory prepared mixtures using the developed HPLC–DAD method

From: An innovative combination of Box-Behnken design and ecofriendly approaches for the simultaneous determination of aspirin, clopidogrel, atorvastatin and rosuvastatin in their fixed-dose combination tablets

Taken (μg/mL)

AUP

Found (μg/mL)

Recovery %

ASP

ROS

CLP

ASP

ROS

CLP

ASP

ROS

CLP

ASP

ROS

CLP

1.5

0.1

0.75

2.077

0.128

0.583

1.488

0.100

0.749

99.20

100.00

99.87

5

0.5

5

6.007

0.533

3.831

4.952

0.494

4.971

99.04

98.80

99.42

7.5

1

7.5

8.873

1.048

5.752

7.478

0.996

7.468

99.71

99.60

99.57

15

2

7.5

17.278

2.089

5.752

14.886

2.009

7.468

99.24

100.45

99.57

25

5

25

28.722

5.125

19.21

24.974

4.964

24.962

99.90

99.28

99.85

50

10

35

57.100

10.334

26.953

49.987

10.035

35.027

99.97

100.35

100.08

        

Mean

99.51

99.75

99.73

        

 ± SD

0.398

0.642

0.244

        

 ± RSD%

0.400

0.643

0.245